Connect

Universal Reader Assistant v2.6 User Guide

12

Serial Readers

Figure 4:

Connecting to a Serial Reader

Finding the assigned COM port

In order to connect to a serial reader (USB Reader, Vega, M5e/M6e devkits) the correct

COM port must be selected from the drop down next to the Connect button. In order for
the associated COM port to be displayed the reader must have been connected to the
host prior to starting URA. If not, you can click Refresh to try and re-detect COM ports in
use. The specific value depends on what the host system has assigned the new
connection, typically it will be the last value in the list.

Baud Rate

If the reader is using a TTL/RS232 connection and you know the baud rate of reader

being connected to you can select it prior to connecting. If you donʼt URA will attempt to
figure it out. Once connected you can change the baud rate for faster communications, if
supported.

For native USB connections the baud rate setting does not apply.

Region

Once the connection is established the Status LED should change to YELLOW and the

Region

selection in the Connect section will change to the default region of the connected

reader, similar to Figure 3. For Serial Readers the region can be changed.