3 input and output signals, 1 input and output signals – CITIZEN PPU-231 User Manual

Page 41

Advertising
background image

PPU-231 User’s Manual

28

CITIZEN

6.3

Input and Output Signals

6.3.1

Input and Output Signals

(1) Input signals to the printer

• DATA

: 8-bit parallel signal (Active: “High”)

• STROBE : Strobe signal to read the 8-bit data (Active: “Low”)
• RESET

: Signal to reset the entire printer (Active: “Low”); 1 ms or more

(2) Output signals from the printer

• ACK

: 8-bit data request signal. A pulse signal to be output at the end of the BUSY signal

(Active: “Low”)

• BUSY

: Signal to indicate that the printer is busy. Input new data when it is "Low."

(Active: “High”)

• FAULT

: Turned to "Low" when the printer has an alarm. At this time, all the control circuits in

the printer stop. (Active: “Low”)

• PE

: Output if the printing paper has run out or is running out. (Active: “High”)