Esc c 5 n, Esc d n – CITIZEN PPU-231 User Manual

Page 73

Advertising
background image

PPU-231 User’s Manual

60

CITIZEN

ESC c 5 n

[Function]

Enabling/Disabling Panel Switches

[Code]

<1B>H<63>H<35>H<n>

[Range]

{0

≤ n ≤ FF} Data is described in Hex code.

[Outline]

Selecting the LF switch valid/invalid.

• "n" is valid only in the lowest bit (n0).
• "n" bit means the followings.

n0

Condition

0 LFSW

valid.

1

LFSW invalid.

[Caution]

When the panel switch is disabled with this command, the LF switch is disabled.

Therefore, the paper cannot be fed by operating the LF switch.

[Default]

• The initial value of n is "0".

[Sample Program]

LPRINT CHR$ (&H1B) + "c5" + CHR$ (0) ;

………… When enabling the LF switch

LPRINT CHR$ (&H1B) + "c5" + CHR$ (1) ;

………… When disabling the LF switch

ESC d n

[Function]

Printing and Feeding the paper by n lines

[Code]

<1B>H<64>H<n>

[Range]

* {0

≤ n ≤ FF} Data is described in Hex code.

[Outline]

Prints data inside the buffer and feeds paper by n lines.

• Specified line does not remain.
• The beginning of the line is to be considered as the next printing start position.

[Default]

• The initial value is not defined.

[Sample Program]

LPRINT "AAAAA"

LPRINT CHR$ (&H1B) + "d" + CHR$ (2) ;

LPRINT "AAAAA" + CHR$ (&HA) ;

[Print Results]