Introduction, Features, Tycon power systems – Tycon Power TP-MS608/616 User Manual

Page 3

Advertising
background image

User’s Manual

TP-MS608/616

3

TYCON POWER SYSTEMS


1. Introduction

TYCON’s family of Power over Ethernet PSE (Power Sourcing Equipment), injects

power over data-carrying Ethernet cabling. The TP-MS608/616, support 8 and 16 ports

respectively in a 10/100/1000BaseTx Ethernet network, over TIA/EIA-568 Category

5/5e/6 cabling. DC operating power, for data terminal units, is fed over data pairs of the

cabling (4/5 and 7/8). This allows greater flexibility in the locating of network devices

and significantly decreasing installation costs in many cases.

The TP-MS608/616 follows the IEEE 802.3af/IEEE 802.3at and is completely

compatible with existing Ethernet switches and networked devices. Normally powers

PDs (Powered Devices) that are Power over Ethernet enabled or are equipped to

receive power over Ethernet. The PSE tests whether a networked device is

PoE-capable, power is never transmitted unless a Powered Device is at other end of

the cable. It also continues to monitor the channel. If the Powered Device does not

draw a minimum current, because it has been unplugged or physically turned off, the

PSE shuts down the power to that port. Devices that are not equipped to receive power

over Ethernet may require an external splitter in order to be powered. Contact Mstronic

for such a splitter.


Features

8/16 port Power Sourcing Equipment ( power over Ethernet Hub)

Support 8/16 ports full load, max. 576W

AC input (100-240 VAC, 50/60 Hz)

IEEE802.3af/IEEE 802.3at compliance, Power over Ethernet Mid-Span mode

Remote power feeding of Ethernet terminals up to 100 meters

Auto detect PD, and support manual detect PD

Centralized power distribution for PoE powered Device (PD)

Independent overload and short-circuit protection per channel

Supports IEEE 802.3af/IEEE 802.3at non-standard device

Auto refresh port status and support Plug and Play feature for PD

Standard 19” or 23” rack mountable

DIY upgrade from 8 port to 16 port available

Remote manage up to 8 units via TCP/IP protocol

DC input available, can work with battery, non-interrupt performance.

Advertising