Led indicators, Tycon power systems – Tycon Power TP-MS608/616 User Manual

Page 5

Advertising
background image

User’s Manual

TP-MS608/616

5

TYCON POWER SYSTEMS


The Front Panel of the TP-MS608/616 consists of 8/16 x RJ-45 Ethernet ports (data),

8/16 x RJ-45 PoE ports (data + power), 8/16 x LED port indicators, one LED power

indicator and one RJ-45 remote control port(include one LED).





LED Indicators

The LED Indicators gives real-time information of systematic operation status. The

following table provides descriptions of LED status and their meaning.

LED

Status

Color

Description






RJ45


On


Green

A network device is

detected(10/100/1000 Mbps)

but no communication activity is

detected


Blinking


Green

The Ethernet port is transmitting

to, or receiving package from

another device

Off

--

No device is detected


Power

On

Green

Power feeding normally

On

Red

Power or fan alarm

Off

--

Power off






Ports

On

Green

Power feeding

Blinking

Orange

Detecting

On

Orange

The port has been shutdown

No power feeding

On

Red

Alarm

No power feeding

Off

--

Unknown device attached

No power feeding


Table 2-1. The Description of LED Indicators