Output characteristics – Zippy GSM-7450P User Manual

Page 35

Advertising
background image

HG2, HP2, GSM and PSL

Ver. 2.0


- 35 -

INPUT CHARACTERISTICS:

GSM-6550P/6600P(G1)

VOLTAGE: 90 ~ 264 VAC FULL RANGE.

FREQUENCY: 47 ~ 63 Hz.

INPUT CURRENT: 9.0/10.0 A FOR 115 VAC, 4.5/5.0 A FOR 230 VAC.

INRUSH CURRENT: 65 A MAX. FOR 115 VAC, 125 A MAX. FOR 230 VAC.

OUTPUT CHARACTERISTICS:

LOAD LINE

RIPPLE & NOISE

MAX.[P-P]

5V

3%

1%

60mV

12V

3%

1%

100mV

5%

1%

100mV

5%

1%

100mV

3.3V

3%

1%

60mV

+5VSB

5%

1%

60mV

REMARK: +5V and +3.3V Max. Current: 50A

+12V TOTAL OUTPUT MAX. 40A.

TOTAL OUTPUT SHOULD NOT EXCEED 550W/600W FOR GSM-6550P/6600P.

*** WHEN PERFORMING CROSS REGULATION TEST, IT IS REQUESTED TO SET THE HIGHER OUTPUT

CHANNEL AT 90% MAXIMUM AND THE LOWER OUTPUT CHANNELS AT 20% MININUM OF RATED
SPEC.

TEMPERATURE RANGE: OPERATING 0

0

C --- 50

0

C, STORAGE –20

0

C --- 70

0

C.

HUMIDITY: 10 ~ 90 % RH.

HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & 90 VAC INPUT VOLTAGE.

DIELECTRIC WITHSTANDING VOLTAGE:

PRIMARY TO SECONDARY: 1800VAC FOR 1 SEC.
PRIMARY TO FG: 1800VAC FOR 1 SEC.

EFFICIENCY: 70% TYPICAL, AT FULL LOAD, 115VAC.

POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms.

OVER LOAD PROTECTION: 110 ~ 150% MAX.

OVER CURRENT PROTECTION:

+5V

33 A ~ 45 A, + 3.3V

33 A ~ 45 A, 12V

44 A ~ 66A

OVER VOLTAGE PROTECTION:
+5V

5.7V ~ 6.2V, 3.3V

3.7V ~ 4.1V, 12V

13.3V ~ 14.3V

EMI: MEET FCC CLASS B, CISPR22 CLASS B.

SAFETY: UL 60950, CSA 22.28 NO950-95, TÜV EN-60950.

ACTIVE POWER FACTOR CORRECTION MEET IEC-1000-3-2 CLASS D

REMOTE ON / OFF CONTROL.

SHORT CIRCUIT PROTECTION: SHUTDOWN AND LATCH.

BUILT-IN ACTIVE POWER FACTOR CORRECTOR.

COOLING: ONE 80 mm DC BALL BEARING FAN.

DIMENSION: 86(H) X 150(W) X 160 (D) mm (STRETCH PS/2, EPS12V).