Output characteristics, Specification – Zippy GSM-7450P User Manual

Page 7

Advertising
background image

HG2, HP2, GSM and PSL

Ver. 2.0


- 7 -


INPUT CHARACTERISTICS:

HG2-6400P(G1)

VOLTAGE: 90 ~ 240 VAC FULL RANGE.

FREQUENCY: 47 ~ 63 HZ.

INPUT CURRENT: 8.0 A (RMS) FOR 115VAC, 4.0 A (RMS) FOR 230VAC.

INRUSH CURRENT: 65A MAX. FOR 115 VAC, 125A MAX. FOR 230 VAC.

OUTPUT CHARACTERISTICS:

LOAD LINE

RIPPLE & NOISE

MAX.[P-P]

5V

5%

1%

50mV

12V

5%

1%

120mV

5%

1%

150mV

5%

1%

150mV

3.3V

5%

1%

50mV

+5VSB

5%

1%

50mV

REMARK: OUTPUT CURRENT OF +5V & +3.3V COMBINED SHOULD NOT EXCEED 45A.

SPECIFICATION:

TEMPERATURE RANGE: OPERATING -10

--- 45

HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE.

DIELECTRIC WITHSTANDING VOLTAGE:

PRIMARY TO SECONDARY : 3000VAC FOR 1 MIN.

PRIMARY TO FG : 2200VAC FOR 1 MIN.

EFFICIENCY: 70% TYPICAL.

POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms.

OVER LOAD PROTECTION: 130 +/- 20%.
OVER VOLTAGE PROTECTION:
+5V

5.7V ~ 6.5V, 3.3V

3.9V~ 4.3V, 12V

13.6V ~ 15V.

SHORT CIRCUIT PROTECTION: +5V, -5V, +12V, -12V, +3.3V.

EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B.

SAFETY: MEET UL 60950, CSA C 22.2 NO. 60950, TUV EN-60950,

CCC GB4943-1995/GB9254-1998/GB17625.1-1998
ACTIVE POWER FACTOR CORRECTION MEET IEC-1000-3-2 CLASS D

REMOTE ON / OFF CONTROL.
THE UNIT SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE / ENABLE
ALL OUTPUT VOLTAGES (EXCLUDE +5V STANDBY),
AS LOGIC LEVEL IS LOW, OUTPUT VOLTAGES WERE ENABLE,
AS LOGIC LEVEL IS HIGH, OUTPUT VOLTAGES WERE DISABLE

ADVANCED THERMAL & ACOUSTICS CONTROL FEATURES..

3.3V / 5V REMOTE SENSING.

COOLING: ONE 80mm DC BALL BEARING FAN.

DIMENSION: 140 (D) x150 (W) x 86 (H) mm (PS/2).