Zippy GSM-7450P User Manual

Page 36

Advertising
background image

HG2, HP2, GSM and PSL

Ver. 2.0


- 36 -



INPUT CHARACTERISTICS:

PSL-6720P(G1)

VOLTAGE: 90 ~ 264 VAC FULL RANGE.

FREQUENCY: 47 ~ 63 Hz.

INPUT CURRENT: 12.0 A FOR 115 VAC, 5.0 A FOR 230 VAC.

INRUSH CURRENT: 75 A MAX. FOR 110 VAC, 150 A MAX. FOR 220 VAC.


OUTPUT CHARACTERISTICS:

LOAD LINE

RIPPLE & NOISE

MAX.[P-P]

5V

5%

1%

60mV

12V

5%

1%

120mV

5%

1%

120mV

5%

1%

120mV

3.3V

5%

1%

60mV

+5VSB

5%

1%

60mV

+5V and +3.3V MAX. power: 230W Total power: 720W (MAX)

*** WHEN PERFORMING CROSS REGULATION TEST, IT IS REQUESTED TO SET THE HIGHER OUTPUT

CHANNEL AT 90% MAXIMUM AND THE LOWER OUTPUT CHANNELS AT 20% MININUM OF RATED
SPEC.

TEMPERATURE RANGE: OPERATING 0

0

C --- 50

0

C, STORAGE –20

0

C --- 80

0

C.

HUMIDITY: 10 ~ 90 % RH.

HOLD UP TIME: 17 ms MINIMUM AT FULL LOAD & 90 VAC INPUT VOLTAGE.

DIELECTRIC WITHSTAND: PRIMARY TO SECONDARY: 1800 VAC FOR 1 SEC.

PRIMARY TO FG: 1800 VAC FOR 1 SEC.

EFFICIENCY: 71% TYPICAL, AT FULL LOAD, 115VAC.

POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms.

OVER LOAD PROTECTION: 110 ~ 150% MAX.

OVER VOLTAGE PROTECTION:
+5V

5.7V ~ 6.3V, 3.3V

3.9V ~ 4.3V, 12V

13.6V ~ 15V.

EMI: MEET FCC CLASS B, CISPR22 CLASS B.

SAFETY: UL 60950, CSA 1402C & CSA950, TÜV EN-60950, CB IEC-60950: 1999, CCC GB4943-2001,
CCC GB9254-1998, CCC GB17625.1-2003

POWER LINE TRANSIENT: EN61000-4-2(ESD) CRITERION B, 4KV BY CONTACT, 8KV BY AIR.

EN61000-4-4(EFT) CRITERION B, 1KV. EN61000-4-5(SURGE) CRITERION B, LINE-LINE 1KV.

ACTIVE POWER FACTOR CORRECTION MEET IEC-1000-3-2 CLASS D

REMOTE ON / OFF CONTROL.

SHORT CIRCUIT PROTECTION: SHUTDOWN AND LATCH.

I

2

C FEATURES (OPTIONAL).

COOLING: ONE 80 mm DC BALL BEARING FAN.

DIMENSION: 86(H) X 150(W) X 220 (D) mm (STRETCH PS/2).

Advertising