DIN Rail 50 Watt Cresnet

®

Power Supply

Crestron DIN-PWS50

Fuse
Replacement

If the DIN-PWS50 does not power up when it is plugged into an AC
outlet, the fuse may need to be replaced. The fuse holder is located on the
front panel, under the cover in the lower left corner. To replace the fuse:

1. Disconnect power to the DIN-PWS50.
2. Remove the cover from the lower left corner on the front of the

DIN-PWS50.

3. Remove the defective fuse from the fuse holder and replace with a

new one.

CAUTION: Use only time lag type fuses, 3.15 Amps / 250 Volts.
Failure to do so may cause damage to the DIN-PWS50.

4. Replace the fuse cover.
5. Connect power to the DIN-PWS50.

12