Installation, Hp-60, Front of machine – B&C Technologies HP Series Commercial User Manual

Page 21

Advertising
background image

Installation

Mounting Bolt Installation

20

Mounting Bolt Installation

The HP-60 requires the use of 3/4-10 x 8” bolts. Embed the bolts in 3500 psi reinforced
concrete with a minimum of 12” thickness. The threaded end of the bolt should extend 2
inches from the surface of the floor. As an option, a welded bolt locating fixture is available
(rebar frame). This rigid welded assembly is made of reinforcing rod (rebar) and is designed
to be encased in concrete.

FRONT OF
MACHINE

HP-60

16.93

[430.00]

20.87

[530.00]

31.50

[800.00]

35.43

[900.00]

31.89
[810]

36.10

[917]

38.11

[968]

47.67

[1210.83]

44.82

[1138.46]

16.93

[430.00]

20.87

[530.00]

31.50

[800.00]

35.43

[900.00]

23.23

[590]

28.74

[730]

31.22

[793]

42.37

[1076.15]

39.14

[994.03]

FRONT OF
MACHINE

HP-60

Advertising