Installation – B&C Technologies HP Series Commercial User Manual

Page 28

Advertising
background image

27

Installation

External Chemical Supplies

The supply compartment on the B&C HP
models is located on the front of the
machine. Supply cups can be accessed by
opening the dispenser lid. The supply cups
can be removed and filled as desired.
Supply compartments are numbered
1,2,3,4 and 5 from the left of the machine
to the right for the optional 5 cup system..

External supply connections for the B&C
HP washer-extractors are located on rear of
the machine at the vacuum breaker. Hose
connections should be made via the
threaded connectors. See figure.
1.

Remove plugs from base. See
figure.

2.

Install the supplied chemical
nipple, using teflon tape.

3.

Insert tubes onto the nipples, using
small hose clamps or wire ties to
prevent the hose from slipping off.

The chemical flush water valve (relay 12)
should be used with each chemical signal
(see the EL6 programming manual for
details).

Advertising