Converting gas types, de-50 and larger, 2 converting gas types, de-50 and larger – B&C Technologies DE Series Commercial User Manual

Page 43

Advertising
background image

Figure 8.1: DE Series Burner Detail

11. Restore gas and electricity.

12. With burner operating, immediately check for leaks with soap solution.

8.1.2

Converting Gas Types, DE-50 and Larger

DE-50 and larger machines will require p/n 250-304 regulator kit for propane, or p/n 250-306
regulator kit for natural gas.

IMPORTANT:

When changing gas types, burner orifices/nozzles must also be changed.

Refer to table 8.1 on page 42 for correct part numbers.

1. Partially depress and turn gas cock dial to OFF.

2. Remove (refer to figure 8.3 on page 41):

(a) Two screws through regulator

(b) Regulator

(c) Gasket

3. Install Gasket, cover plate and 2 screws from conversion kit.

4. Turn gas cock to ON.

5. Leak test with soap solution while main burner is on.

40