Installation

Electrical Connection

14

Electrical connections should be made by a
qualified electrician in accordance with all

applicable codes or requirements. Use a

separate branch circuit to power each

machine. Do not share circuits with lighting

or any other equipment.

A shielded liquid tight or approved flexible

conduit with proper conductor of correct

size installed in accordance with National

Electric Code (USA) or other applicable
codes is required. The connection must be

made by a qualified electrician using the

wiring diagram provided with the machine.

For personal safety and for proper

operation, the machine must be grounded

in accordance with state and local codes

and in the USA in accordance with the

National Electric Code, article 250-96.

The ground connection must be to a proven

earth ground, not to conduit or water pipes.

Do not connect the ground to the neutral

(N) leg at the terminal strip (if so equipped).

If a DELTA supply system is used, the high

leg should be connected to L3, since

control voltage is derived from L1 and L2.

Insure that the control transformer taps are

connected in accordance with the incoming

line voltage. Verify connections as shown

on the schematic with each machine.

Electric Heat Models

Rating

Model

Breaker Size

Full Load Amps

IP-1478

100

87

IP-1485

100

96

IP-14100

125

111

IP-1478

50

43

IP-1485

50

48

IP-14100

100

55

Gas/Steam Heat Models

Rating

Model

Breaker Size

Full Load Amps

IP-1478

15

4

IP-1485

15

5

IP-14100

15

7

IP-1478

15

2

IP-1485

15

3

IP-14100

15

4

208-230V, 50/60Hz

380-480V, 50/60Hz

208-230V, 50/60Hz

380-480V, 50/60Hz