Installation, Warning, Exhaust requirements – B&C Technologies IP Series Commercial Ironer User Manual

Page 17

Advertising
background image

Installation

Exhaust Requirements

17

For best results, install the ironer near an
outside wall in order to keep the exhaust

duct length as short as possible, and to

provide a source of make-up air. Neither

the rear nor the sides of the ironer should

be blocked. Blocking the air inlets prevents
proper combustion, and will yield poor

results, and possibly harmful combustion

byproducts.

HORIZONTAL EXHAUST

SHOULD NOT EXCEED 20 FEET

NOTE A

INSPECTION
DOORS

2 X D CLEARANCE

D

WALL

EXHAUST MUST ENTER MAIN
DUCT AT A 45° ANGLE

NOTE A:

THE DUCT MUST BE CENTERED WITHIN THIS OPENING

OPENING MUST BE 2 INCHES LARGER THAN DUCT ALL THE WAY AROUND

VERTICAL EXHAUST

NOTE A

ROOF

2 X D CLEARANCE

D

WARNING

Toxic and fire hazzards.

Machine produces gases,
fumes and lint which may
be toxic or catch fire and
could result in serious
injury or death.

Vent exhaust outdoors and
regularly clean lint away
from machine.