Programming

Cycle Programming (continued)

When modifying a cycle time, a time must be
entered for each segment. To skip a segment or
spin, enter 00 for the time and press the Start
key. The following table shows the range of
time allowed for each segment and spins, as
well as the allowed temperature range for
machines equipped with auxiliary heat.

Note that spin times are programmed in
seconds for intermediate spins following
Prewash, Wash, and Fills 1 through 5. The
final spin, following Fill 6 is programmed in
minutes.

To begin programming, press the Up key shows
the segment to be edited, then press the Start
key.

For the Prewash segment, you can select either
PREU (normal Prewash) or FLUS (overflow fill
Prewash). If Overflow Prewash is selected, the
fill valves will remain on for the duration of the
Prewash step. Press the Start key to make your
selection.

If the Spray Rinse option is enable in Setup,
you have the option of Spray Rinse or Dilution
Rinse during Fill 1 through Fill 5. The display
shows SRIN for spray rinse or dRIN for dilution
rinse.

Func tion

Minimum

Maximum

Prewash

2 minutes

30 minutes

Wash

2 minutes

20 minutes

Fill 1

2 minutes

15 minutes

Fill 2

2 minutes

15 minutes

Fill 3

2 minutes

15 minutes

Fill 4

2 minutes

15 minutes

Fill 5

2 minutes

15 minutes

Fill 6

2 minutes

15 minutes

Intermediate Spin

30 seconds

120 seconds

Final Spin

1 minute

10 minutes

Temperature

75F / 25C

200F / 93C

Time and Temperature Parameters

Display

Fill Type

HFIL

Hot Fill

CFIL

Cold Fill

BFIL

Warm Fill

Fil l Temperature Options

After you have selected the appropriate fill
temperature, press the Start key.

Now you can select the Fill level by using the
Up or Down key. Select your fill level
according to the following table.

Display

Fill Level

LOLE

Low Level

HILE

High Level

Fil l Level Options

Note that if you selected FLUS for the Prewash
segment, this selection is skipped. After your
Fill level selection, press the Start Key.

Next select the desired Supply option. See the
table.

11

Display

Supply

SUP0

No Supply

SUP1

Supply 1

SUP2

Supply 2

SUP3

Supply 3

SUP4

Supply 4

SUP5

Supply 1 & 2

SUP6

Supply 2 & 3

SUP7

Suppply 3 &4

S uppl y Options

Supply 4 & 7 are only
avaliable if is Supply 4 was
enabled in Setup

Use the Up and Down keys to select the fill
temperature. The following table shows the
available options.