Default settings and default programs, Default values, Chapter 6 default settings and default programs – B&C Technologies M720 Dryer Control (DE, DP, DI Series) User Manual

Page 46: 1 default values

Advertising
background image

Chapter 6

Default Settings and Default Programs

6.1

Default Values

Because the programmed language can vary, no default program names are set, except for program
100, which will be called Single cycle.

Table 6.1: M720 Factory Default Values

Parameter

Description

Value

1

Drying method

TIME

3

Min. drying time

10 m

4

Max. drying time

45 m

5

Drying time

40 m

7

Dry temperature

167

o

F / 75

o

C

8

Offset sensor 2

2

o

F /

o

C

9

Offset infrared

4

o

F /

o

C

10

Humidity dry val.

15.00%

18

Cooldown time

10 m

19

Cooldown temp.

95

o

F / 35

o

C

23

Drum direction

REV

24

Drum speed

100.00%

25

Drum stop time

1 s

26

Drum run time

45 s

29

Anti crease funct.

YES

32

Max. temp. rise

0

o

/m

33

Max. temp. fall

0

o

/m

In the default programs, some parameter values are set to a different value to provide different
programs to start with. The following default programs are available: