Pushing the E

NTER

key without the S

HIFT

key (see item 10) means enter or accept. If the key

is pressed in combination with the S

HIFT

key (see item 10), is becomes the C

LEAR

function.

The E

NTER

key is used to confirm a choice or an adjustment. For example, if another program

is selected from the list, the E

NTER

key must be pressed to confirm the choice. This is the

same when a parameter value is changed. When a new value is entered, this value must be
confirmed with the E

NTER

key, otherwise the change in value will not be stored.

The C

LEAR

key is used to cancel an entered value. For example, when a parameter has been

changed in error, pressing the C

LEAR

key cancels the change. If the E

NTER

key is pressed in

combination with the S

HIFT

key, the old parameter value will be restored.

10. S

HIFT

key

This key is used to access the secondary function of a key. When a key is pressed without
the S

HIFT

key, it functions normally, as indicated in white on the key. If a key is pressed in

combination with the S

HIFT

key, the secondary function is activated, indicated by function in

the same color as the S

HIFT

key. To use the secondary function of a key, first push the S

HIFT

key, then push the key itself while holding the S

HIFT

key. Release the key then release the

S

HIFT

key.

11. Numeric keypad

These buttons can be used to enter a numeric value. For example in the program selection
screen a program number can be entered with these buttons. Entering a new parameter value
and entering a password can also be done with these buttons.

The numeric keypad buttons are also used for editing the name of a program. In this case
they are used to enter characters (see Section 4.5.2 on page 25).

12. Temporary temperature set-point change

Sometimes it is necessary to manually adjust the temperature to a higher or lower set-point.
If the S

HIFT

key (see item 10) is pressed in combination with the INCREASE TEMPERA-

TURE (

) key, the current temperature set-point will be increased by 5 degrees Fahrenheit

(or 2.8 degrees Celsius). If the S

HIFT

key (see item 10) is pressed in combination with the

DECREASE TEMPERATURE key (

), the current temperature set-point will be decreased

by 5 degrees Fahrenheit (or 2.8 degrees Celsius). The controller uses Fahrenheit units in-
ternally but the interface units are configurable as either Fahrenheit or Celsius. When the
interface temperature units is set to Fahrenheit increments of 5 degrees increase or decrease
will be displayed. When the interface temperature units is set to Celsius the display will
sometimes show an increment of 2 degrees and sometimes an increment of 3 degrees. This
is because 5 degrees Fahrenheit is equal to 2.8 degrees Celsius but DOES NOT influence the
actual increment, which is always 5 degrees Fahrenheit.

Please note that these changes in set-point are temporary. They do not change the pro-
grammed value in the active program. This means that the next time the program runs,
the temporarily changed values will be forgotten. Also, if a temporary change is made in
the drying cycle of the program, this does not influence the cool-down temperature setting
adjusted.

13. Temporary time change