TURN GAS ON.
PILOT BURNER LIGHTS?

MAIN VALVE OPENS?

SYSTEM OK

IGNITER WARMS UP
AND GLOWS RED

PILOT VALVE
OPENS

START
• TURN GAS SUPPLY OFF
• SET THERMOSTAT TO

CALL FOR HEAT

SV9501/SV9601 IS
POWERED
(24 VAC NOMINAL)

YES

CHECK:
• LINE VOLTAGE POWER
• LOW VOLTAGE TRANSFORMER
• LIMIT CONTROLLER
• THERMOSTAT
• WIRING
• FAN PROVING SWITCH
ON COMBUSTION AIR BLOWER

UNPLUG IGNITER
MEASURE VOLTAGE AT
TWO BOTTOM TERMINAL OF
SV9501/SV9601
(24 VAC NOMINAL)

YES

YES

YES

YES

YES

NO

NO

NO

YES

NO

NO

NO

Troubleshooting Honeywell SV9501/SV9601

Hot Surface Pilot System (JVH only)

REPLACE IGNITER

REPLACE SV9501/SV9601

MEASURE VOLTAGE TO
SV9501/SV9601.
VOLTAGE MUST BE AT LEAST
19.5 VAC.

REPLACE IGNITER

REPLACE IGNITER SENSOR AND
RETAIN: RESTART TROUBLE-SHOOTING
SEQUENCE. DOES MAIN VALVE OPEN?

DISCARD OLD IGNITER SENSOR

NO

NO

NO

REPLACE

SV9501/

SV9601

CHECK
TRANS-FOR-
MER, LINE
VOLT SUP-
PLY

REPLACE
SV9501/
SV9601.
SAVE OLD
IGNIT-
ER-SENSOR
FOR
SERVICE.