Bradford White BJVS225 User Manual

Page 35

Advertising
background image

Brute Mini JV

Page 35

Air Vent

A device used to purge air from the Circuit. Should be

located at the highest point in the Circuit.

Branch

The section(s) of supply and return piping, including

the heat distribution units connected directly to the

trunk. Also referred to as a “zone”.

By-Pass

A section of pipe (including an adjustable valve) that

diverts part of the water flow from undersized piping

to the boiler. Adjusted to maintain minimum flow

requirement (GPM) through the boiler.

Circuit

Entire water circulation piping, beginning and ending

at the boiler (Series Loop System).

Expansion Tank (Compression Tank)

Installed in the circuit to accommodate excess water

produced by heat expansion.

Heat Distribution Units

Transfers heat from the water supplied by the boiler

to the area to be heated through the use of baseboard,

convector, radiator, finned tube. Also known as

“radiation”.

Isolation Valve

Used to isolate the boiler from the circuit. It minimizes

the amount of water drained from the system.

Primary-Secondary Piping

Two or more interconnecting circulating loops,

each with its own pump. Primary =System Circuit;

Secondary=Boiler Circuit.

Reverse-Return Piping

Balanced, equal flow (first in, last out) piping. Utilized

with multiple boilers and/or radiation. Applied with

single system pumps, or primary-secondary pump.

System Purge Valve

A device used to purge air from the circuit. Should be

located as close as possible to the cold water feed, but

not immediately after the cold water feed.

Temperature Controllers

The primary temperature controller maintains all

normal heating operations.

A secondary, mechanical high-limit aquastat

provides safe shutdown, should the primary

controller fail.

Trunk

The section of piping which connects the boiler return

and supply with the branch(es). Also known as a

“main” or “header”. Should be same size as boiler

inlet/outlet connections.

Zone Pump

Circulators installed in branch piping that divert

hot water coming from the boiler into various areas

(zones) of a building.

Zone Valve

Diverts hot water from the boiler into various areas

(zones) of a building.

10A Glossary of Terms

SECTION 10. Replacement Parts

Advertising
This manual is related to the following products: