Chapter 4 Board and System Configuration

Parameters that define customized ISDN-PRI profiles.
Label

Description

cnx_profile_begin

Up to 5 different ranges for cnx_profile can be configured.

phone

The first phone number of the range with this profile. It should not exceed 30 characters
and "none" specifies the null string.

size_range

The number of phone numbers in the range with this profile. Values range from 1 to 255.
No label is equivalent to the value 0.

cnx_type

Type of incoming call. Possible values are analog, digital, v110, v120 or a combination
of the four separated by the pipe, "|".

cnx_profile_end

ends definition of customized ISDN-PRI profile.

FIG. 4.2 ISDN-PRI PROFILE PARAMETERS

Parameters that define and apply to DSP profiles.
Label

Description

dsp_profile_begin

Marks the beginning of a digital signal processor profile. All parameters following this
label apply only to this dsp profile until dsp_profile_end is reached.

profile_id

A number between 1 and 5 which labels the dsp profile for later reference.

config_string

Commands sent to the dsp. It should not exceed 80 characters.

dsp_profile_end

Marks the end of the configuration parameters for a digital signal processor profile. See
comments for dsp_profile_begin above.

FIG. 4.3 DSP PROFILE PARAMETERS