Chapter 4 Board and System Configuration

Label

Description

onhook_timer

Valid only for CAS in Brazil. Valid values are 20-255, in units of a fraction of a second.
When the PC400 answers an incoming call it waits for the period defined by
answer2_timer, then it hangs up. Next, it waits the period defined by onhook_timer and
reconnects. The line remains active if the call was not a collect call. This is necessary
because in Brazil a collect call is accepted by simply remaining on the line.

answer2_timer

Valid only for CAS in Brazil. Specifies the time that should elapse before answering an
incoming call. Valid values are 15-255, in units of a fraction of a second. See
description of onhook_timer.

trunk_number

Principal phone number assigned to the ISDN trunk line. Use the value

none

for this

parameter if the incoming number should not be confirmed by the PC400. This is
recommended when the provider does not send the trunk line number in the incoming
call message. The value should not exceed 30 characters.

switch_type

Switch type when PRI signaling is used. au1 (for Australia), ets (for Europe ETSI), vn6
(for France), tr6 (for Germany), dms (for USA – NorTel DMS-100), 5ess (for USA – AT&T
Custom), ntt (for Japan), n_isdn2 (for USA – NI-2), hkt (for Hong Kong) and 4ess (for
USA – AT&T).

idle_timeout

For PRI signaling mode, specifies the idle timeout, in minutes, to drop one call. The
value should not exceed 127 and 0 indicates no timeout.

t200

For PRI signaling mode, specifies the ISDN T200 parameter, which may not exceed 255.

n200

For PRI signaling mode, specifies the ISDN N200 parameter, which may not exceed 255.

t203

For PRI signaling mode, specifies the ISDN T203 parameter, which may not exceed 255.

interf#_end

Marks the end of the configuration parameters for the first interface. See comments for
interf#_begin above.

FIG. 4.4 INTERFACE PARAMETERS (CONT.)