Connection to pnozmulti, Connection to pss, Teaching in the actuator – Pilz PSEN cs4.2a User Manual

Page 13: Installation

Advertising
background image

PSEN 4.2a/b/p/M12

Operating Manual PSEN 4.2a/b/p/M12
22188-EN-02

13

Connection to PNOZmulti

Safety gate with switch type 3

I0, I1: Inputs OSSD

I2: Signal input

I2

I0

I1

grün

grau

gelb

Connection to PSS

Safety gate standard block SB64

I00, I01: OSSD inputs

I02: Signal input

grün

grau

gelb

Teaching in the actuator

The

first actuator detected by the safety switch PSEN cs4.1 is automatically taught in as

soon as it is brought into the response range.

NOTICE
No other actuator may be taught in once this actuator has been taught.

Installation

}

The safety switch and actuator should be installed opposite each other in parallel.

CAUTION!
The unit's properties may be affected if installed in an environment contain-
ing electrically or magnetically conductive material. Please check the oper-
ating distances and the assured release distance.

}

Safety switches and actuators should only be secured using M4 screws with a flat head

(e.g. M4 cheese-head or pan head screws).

}

The actuator should be protected from unauthorised removal and from contamination.

Close the mounting holes using the seals provided.

}

Torque setting: Max. 0.8 Nm.

}

The distance between two safety switches must be maintained (see

Technical De-

tails [

20]

).

Safety switches and actuators

}

Should not be exposed to heavy shock or vibration and

}

Should not be used as a limit stop.