Adjustment, Operation, Error display through flashing codes – Pilz PSEN cs4.2a User Manual

Page 17

Advertising
background image

PSEN 4.2a/b/p/M12

Operating Manual PSEN 4.2a/b/p/M12
22188-EN-02

17

Adjustment

}

The stated operating distances (see

Technical details [

20]

) only apply when the

safety switch and actuator are installed facing each other in parallel. Operating distanc-
es may deviate if other arrangements are used.

}

Note the maximum permitted lateral and vertical offset (see

Operating distances [

7]

and

Lateral and vertical offset [

7]

).

Operation

Check the function of the safety switch before commissioning.
Status indicators:

}

"POWER/Fault" LED lights up green: The unit is ready for operation

}

"Safety Gate" LED lights up yellow: Actuator is within the response range

}

"Input" LED lights up yellow: There is a high signal at both inputs.

Error display through periodic flashing:

}

"Input" LED lights up yellow: the signal switches from high to low at one input, while a

high signal remains on the other input (partial operation).
Remedy: Open both channels of the input circuit.

}

"POWER/Fault" LED lights up red: Error message

Flashing codes for fault diagnostics are output to the "Safety Gate" and "Input" LEDs
(see Error display through flashing codes).
Remedy: Rectify fault and interrupt power supply.

Please note the different switch-on delay after U

B

is applied and after the recovery time of

the sensor and evaluation device.

Error display through flashing codes
The "Safetygate" and "Input" LEDs send flash signals; an error code can be established
from the number and sequence. The "Power/Fault" LED illuminates red.
Each error code is indicated by three short flashes of the "Input" or "Safetygate" LED. After
a longer pause, the LED will then flash at one second intervals. The number of LED flashes
corresponds to a digit in the error code. The error code can consist of up to 4 digits. The
digits are separated by a longer period without flashing. The entire sequence is constantly
repeated.

Number of flashes

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Decimal error code

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0