Orthogonal assembly – Pilz PSEN cs4.2a User Manual

Page 15

Advertising
background image

PSEN 4.2a/b/p/M12

Operating Manual PSEN 4.2a/b/p/M12
22188-EN-02

15

For the next steps you will need the seals as

illustrated.

Use the seals to close the screws' mounting

holes on the actuator

}

(4): Without UL approval

}

(1): For UL approval

Use the seals (2) to close the unused

mounting holes on the actuator.

Use the seals (3) to close the mounting

holes on the sensing face of the safety

switch.

Orthogonal assembly

Drill holes in the mounting surface (see

Di-

mensions [

19]

) and cut threads in the

holes for M4 screws.

Use a screw to fix the safety switch in place.