This dialog allows you to configure the MRP (Memory

Recall Port) on newer versions of the RPM 26v beginning
with firmware rev 2.2.

Each possible MRP pattern is shown as a decimal number

and binary code where 1 represents a switch closure on the
numbered contact. To its right is a drop-down menu for each
input pattern, where you select the Memory to be recalled.

You can cusomize Memory recall values, save them to a

MRP file and load them into future units.

After exiting this dialog with the

OK button, the MRP in

the unit will be updated.

Device > Restore Memories from File

This menu item allows you to restore all Memories and

names to a device from a selected file.

Note: All saved RPM 26v data files are given the default

extension

.RPM.

Device > Lock Device

Lock Device allows you to lock a device to prevent

unauthorized users from making changes to your programmed
settings in the device’s Memories. Although a device is
locked, different presets can still be recalled by selecting
another Memory via the Site Control Panel, the Memory
Recall Port, or by clicking on a desired Memory key on the
button bar with the mouse. The data previously stored in the
device’s Memories, however, can not be changed.

To Lock a device, type in the password in the dialog box

shown above after selecting

Lock Device from the Device

menu. When a device is locked, this icon appears to the right
of the Local Edit button on the button bar.

Device > Unlock Device

This menu selection restores a device to its unlocked state,

allowing changes to the data previously stored in its Memo-
ries. You must type in the correct password before the device
will unlock and the lock icon disappears.