Talkaphone ETP-402V Dual Button Emergency / Information Phone User Manual

Page 25

Advertising
background image

Federal Communications Commission Information

       

 

I. The Talk-A-Phone Co. U. S. A. Service Center is located at 7530 North Natchez

Avenue, Niles, Illinois 60714-3804, telephone number (773) 539-1100, fax number
(773) 539-1241.

XI. Phone Line Specifications

A. MODE I Operation

The following criteria must be met by a phone line to insure proper functionality of the

FCC approved equipment. All voltages use Tip as ground when measuring.
1. On-Hook voltage must be less than or equal to –36 V (-50 V standard).
2. Off-Hook should be recognized in a maximum time of 300 ms.
3. At an Off-Hook voltage of –15 V, the current that is supplied must be no less than

20 mA and no more than 120 mA.

4. Dial tone must consist of 350 Hz and 450 Hz tones at –17 dB ± 0.5%.
5. The telephone line must generate Ring-Back consisting of 440 Hz and 480 Hz

tones at –17 dB ± 0.5%, with a duty cycle of 1.6 seconds on—4.8 seconds off ±
10% interrupted at 20 Hz.

6. The telephone line must generate a busy signal consisting of 480 Hz and 620 Hz

tones at –17 dB ± 0.5%, with a duty cycle of 500 ms on—500 ms off.

7. The telephone line must be able to recognize or send the following frequencies in

order to decode or transmit DTMF:
a) 685 Hz — 709 Hz

Row 1

b) 757 Hz — 784 Hz

Row 2

c) 837 Hz — 867 Hz

Row 3

d) 925 Hz —957 Hz

Row 4

e) 1189 Hz — 1229 Hz

Column 1 (1, 4, 7, *)

f) 1314 Hz — 1358 Hz

Column 2 (2, 5, 8, 0)

g) 1453 Hz — 1501 Hz

Column 3 (3, 6, 9, #)

h) 1607 Hz — 1659 Hz

Column 4 (A, B, C, D)

8. When dialing, the telephone line should require a minimum tone pulse ON time of

40 ms, as well as a minimum between tone gap of 40 ms.

9. The telephone line should support and match with a 600W AC impedance, as

well as a DC resistance of 100 W — 200 W.

10. The telephone line should recognize a 450ms hang-up as a disconnect signal.

B. MODE II and MODE III Operation

Talk-A-Phone phones can be used with most PBX systems with non-standard dial
tones, ring-backs, busy signals and hang-ups.

Advertising
This manual is related to the following products:

ETP-402KV Keypad Emergency Phone, ETP-402KSV Keypad Access Phone, ETP-400 MOD Single Button OEM Emergency Phone, ETP-402KSEV Keypad Access Phone, ETP-402KSE Keypad Access Phone, ETP-402KS Keypad Access Phone, ETP-402K Keypad Emergency Phone, ETP-402CV Dual Button Assistance / Information Phone, ETP-402C Dual Button Assistance / Information Phone, ETP-402 Dual Button Emergency / Information Phone, ETP-401V Single Button Emergency Phone, ETP-401P Swimming Pool Emergency Phone, ETP-401CV Single Button Assistance Phone, ETP-401C Single Button Assistance Phone, ETP-401 Single Button Emergency Phone, ETP-400V MOD2 Single Button OEM Emergency Phone, ETP-400V MOD Single Button OEM Emergency Phone, ETP-400V Single Button Emergency Phone, ETP-400KV Keypad Emergency Phone, ETP-400KSV Keypad Access Phone, ETP-400KSEV Keypad Access Phone, ETP-400KSE Keypad Access Phone, ETP-400KS Keypad Access Phone, ETP-400K Keypad Emergency Phone, ETP-400H-NC Handset Emergency Phone, ETP-400DV Dual Button Emergency / Information Phone, ETP-400 Emergency Phone With One Button, ETP-400DCV Dual Button Assistance / Information Phone, ETP-400DC Dual Button Assistance / Information Phone, ETP-400D Dual Button Emergency / Information Phone, ETP-400CV Single Button Assistance Phone, ETP-400C Single Button Assistance Phone, ETP-400 MOD2 Single Button OEM Emergency Phone, ETP-103V OEM Emergency Phone, ETP-103 OEM Emergency Phone, ETP-100MV Surface Mount Emergency Phone, ETP-100MBV Surface Mount Emergency Phone, ETP-100MB Surface Mount Emergency Phone, ETP-100M Surface Mount Emergency Phone, ETP-100EV Flush Mount Emergency Phone, ETP-100EBV Flush Mount Emergency Phone, ETP-100EB Flush Mount Emergency Phone, ETP-100E Flush Mount Emergency Phone