2functional configuration screen, Functional configuration screen -7, Ion 4.5.2) – CANOGA PERKINS L357 Gigabit Ethernet Service Unit User Manual

Page 27: 2 functional configuration screen

Advertising
background image

EdgeAccess Universal Chassis System

L357 Gigabit Ethernet Service Unit

4-7

4.5.2 Functional Configuration Screen

The Functional Configuration report and menu provides information about the hardware, with options
to set software control. You can only view the options for the Remote module, but you can set
options for the Local L357 to work with the Remote module. For details about how RMTF, LLE, and
LLF interact, see " Section 3.3" on page 3-3. Two reported hardware switch functions depend on the
type of module:

An L357 with a UTP User port ignores the LLE User settings.

An L357 with a fiber User port ignores the User Speed/Duplex settings.

In addition, a system that supports 1000 BASE UTP ports allows only one port set to Master; all
others must be set to Slave.

To access the Functional Configuration screen, see Figure 14 and Table 5 and follow these steps:

1. From the Main Menu, type

1

, "System Configuration," and press <Enter>. The System

Configuration menu appears.

2. From the System Configuration menu type

2

, "Functional Configuration," and press <Enter>.

3. At the Functional Configuration screen, type the number for an item and press <Enter>, then

press <Space> to cycle through the options and press <Enter> to select an option for the Local
L357.

4. To return to the System Configuration menu, press <Esc>.

FUNCTIONAL CONFIGURATION
Local

Remote

Chassis/Slot

4/3B

2/5

User Port Speed/Duplex

1000M/Half

1000M/Half

Switch Settings:

User Port Speed/Duplex

1000M/Full

Autonegotiate

Side Band Mgmt

Enabled

Enabled

LLF Extension to User

Disabled

Disabled

LLF User to Extension

Disabled

Disabled

1) Configuration Option Control

Hardware

Hardware

2) User Port Setting

1000M/Half

Autonegotiate

3) Ext Port Setting

Autonegotiate

Autonegotiate

4) RMTF/LLE

Disabled

Disabled

5) Link Loss Fwd

Disabled

Disabled

6) Remote Configuration

Figure 14. Functional Configuration Screen (UTP to Fiber L357)

Advertising