7link status screen, Link status screen -18, Table 9. diagnostics screen definitions -18 – CANOGA PERKINS L357 Gigabit Ethernet Service Unit User Manual

Page 38: 7 link status screen

Advertising
background image

EdgeAccess Universal Chassis System

L357 Gigabit Ethernet Service Unit

4-18

DIAGNOSTICS

Local

Remote

Chassis/Slot

4/3B

2/5

Loopback Switch Setting:

N/A

N/A

Loop Test MAC Address:

00 40 2A 80 58 32

00 40 2A 80 58 33

1) Loopback Option Control

Software

Software

2) Loopback State

Disabled

Disabled

3) Swap MAC Address

at Loopback Point?

Yes

Yes

4) Recalculate CRC

at Loopback Point?

Yes

Yes

Figure 29. Diagnostics Screen

Table 9. Diagnostics Screen Definitions

Selection

Description

Loopback Switch Setting

Shows hardware setting only when in a Model 1020; Local,
Remote, or Normal

Loop Test MAC Address

Shows unique MAC address for destination of loopback packets

1) Loopback Option Control Set to Hardware (option for Model 1020 only) or Software
2) Loopback State

Set to Local, Remote, or Clear All Loopbacks

3) Swap MAC Address at
Loopback Point?

Set to Yes or No; use to run loopback packets through a switch

4) Recalculate CRC at
Loopback Point?

Set to Yes or No; use to run loopback packets through a switch

4.7

Link Status Screen

Use the Link Status screen to view the current link conditions on the L357. See Figure 31. To view
link status, follow these steps:

1. From the Main Menu, type

3

, "Link Status," and press <Enter>. The Link Status screen appears.

2. When you finish checking the Link Status, press <Esc> to return to the Main Menu.

LINK STATUS

Local

Remote

Chassis

4

2

Slot

3B

5

User Port

Link Up

Link Up

Extension Port

Link Up

Link Up

Figure 30. Link Status Screen

Advertising