1ping generation, 1 ping generation -22, Figure 35. ping generation screen -22 – CANOGA PERKINS L357 Gigabit Ethernet Service Unit User Manual

Page 42

Advertising
background image

EdgeAccess Universal Chassis System

L357 Gigabit Ethernet Service Unit

4-22

Item

Definition

5) Modem/Slip/PPP Baud Rate

Select the baud rate, 9600, 19200, 38400, 57600, or
115200 bps for the modem/SLIP/PPP serial port (standalone
enclosure, only)

6) Modem Initialization String

The default string is "

AT

" (standalone enclosure, only)

7) PING Generation

Access the PING diagnostics screen (standalone enclosure,
only)

8) Static ARP Table

Set or change specific IP and MAC addresses (standalone
enclosure, only)

9) Dynamic ARP Table

View current IP and MAC addresses (standalone enclosure,
only)

4.11.1

PING Generation

Use the PING Generation screen to test the connection to a specific IP address. See Figure 35.

PING Generation

IP Address to PING: 0.0.0.0
PING count (1 to 255, 0 = forever):

0

Figure 35. PING Generation Screen

To use PING to check a connection, follow these steps:

1. From the Main Menu, type

7

, "Utilities," and press <Enter>.

1. From the Utilities menu, type

7

, "PING Generation," and press <Enter>.

2. At the PING menu prompt, set the PING parameters, and press <Enter>.

"

PING response received...

" indicates a good connection;

"

TIMEOUT: Unable to reach [IP address]...

" indicates a faulty connection.

3. To stop the PING , press <Esc>.