CANOGA PERKINS L3xx Media Converter User Manual

Page 7

Advertising
background image

Canoga Perkins Corporation, 20600 Prairie Street, Chatsworth, CA 91311-6008

Phone: (818) 718-6300, FAX (818) 718-6312 www.canoga.com

P/N 6942550 Rev A

Page 7 of 8

through the selections. Set the “Option Control” to “Software” to change settings through
software. Use the ESC button to cancel your selection or to return to the earlier screen.

Canoga Perkins Corp. EdgeAccess Ethernet Media Converter 03-Oct-2005
Model L321-1075 V03.40 F37 Standalone 11:00:54
----------------------------SYSTEM STATUS & CONFIGURATION-----------------------

Local

Remote

Chassis Type

Standalone 1020

Offline

Chassis/Slot

Standalone

CLIM Type

L321-1075

User Port

100 BASE-TX UTP RJ48

Extension Port

100 1310 SM SC 40k 1Fbr

Serial Number

20030275771

Hardware Rev. FD
Power Supply Pri AC 120/240
Power Supply Sec N/A
Fan Status

N/A

Chassis Temperature N/A
Side Band Mgmt No

1) Option Control

Software

2) RMTF/LLE RMTF Enabled
3) Link Loss Fwd Disabled
4) Loopback State Disabled
Hit SPACE: toggle selection. ENTER: accept. ESC: cancel. TAB: change columns
------------------------------------Messages------------------------------------

Alarm Outputs: Major

Figure 11. System Status and Configuration screen

Step 7: Cable Connection

Once the changes are made to the modules, the UTP (Unshielded Twisted Pair) or fiber optic
cables can be installed. Remember that the USR port is the port connected to your local/client
device and the EXT port is the port facing the network/trunk. Connect the fiber to the EXT port.

Figure 12. Fiber optic and UTP cable connection

Step 8: IP Address/Subnet Mask/Default Gateway Set-up

From the Main Menu, type “5” then “enter” to access the SNMP Configuration screen. To
configure the IP address, select “7,” press “enter,” and type the IP address you wish to assign to
the unit. Press enter to accept the changes. The Subnet Mask and Default Gateway must be
entered at this point as well.

Advertising