Power inputs, Power inputs -3 – Dynon Avionics EFIS-D100 Installation Guide User Manual

Page 15

Advertising
background image

Instrument

Installation

EFIS-D100 Installation Guide

3-3

The metal shield around the EDC communication cable is connected to the short black/white
wire emanating from the DB25. Connect this wire to ground.

The EFIS-D100 has three separate power inputs, located on the DB25 EFIS connector. Of the

er is required to operate the instrument. The other two inputs provide

e

Power Inputs

three, only Master Pow
redundancy. Below is a table that explains the three inputs and their purposes. All three of thes
inputs share a common ground signal, wired to pin 3 on the EFIS connector.

EFIS

DB25

pin#

Function

EFIS DB25 wire

color

Description

1 Master

Power

Provides primary power

instrument.

The EFIS-D100 will switch on upon

d

Red

to the

application of power. Connect to a switched
power source. Will not be adversely affecte
by engine cranking.

2 Keep

Alive

Power

Yellow

nd External Backup

as

A very low current power input which is only
used if both Master a
Power are not applied. Keep Alive draws just
enough current to keep the clock running. It
draws less than 1 milliamp of current when
not charging the internal backup battery.
Dynon Avionics recommends not connecting
the Keep Alive wire when the EFIS-D100 h
an internal battery installed or is connected to
a GPS. Keep Alive is only used in
installations with no battery or GPS to keep
the clock running when the unit is powered
off.

3 Master

Ground

Black

.

Connect to ground. Must carry as much as 3
amps

15 External

Backup

Power

(Not wired in

Dynon harness)

is not present. The transition from

ll

.

Will operate the EFIS-D100 only if Master
Power
Master Power to External Backup Power wi
bring up a warning, requiring you to press
ACK within 30 seconds to keep the unit
operating. This warning will also display
when transitioning from either Master or
External Backup to Internal Battery power

Advertising