Voltage, Current, Voltage -15 – Dynon Avionics EMS-D10 Installation Guide User Manual

Page 57: Current -15

Advertising
background image

EMS

Configuration

Voltage

The voltmeter info item reports the voltage that the EMS-D10 reads on its Master Power input
(pin 1 on the EMS 37-pin connector). Because of this, there is no sensor to install or configure.
Simply, select the alarm mode and the analog bar thresholds as described in Alarm and Color
Threshold Configuration on page 5-2. Configure the voltm
eter info bar to display in the desired
location(s), as described in the EMS-D10 Pilot’s User Guide > Global Configuration Settings >
Info Item Configuration section.

Current

If a current sensor has been installed, set the DISPLAY
parameter to ON, otherwise, set it to OFF. First, select
whether your ammeter will be showing positive and
negative currents (-60A TO 60A; used for Location A)
or only positive currents (0A TO 60A; used for
Locations B and C). This will depend on your
installation as mentioned in the Ammeter Shunt installation
section on page 3-12. Select the alarm mode and the analog
bar thresholds as described in Alarm and Color Threshold
Configuration on page 5-2
. Change the SENSOR TYPE to
the correct number using the sensor type table. Configure
the ammeter info bar to display in the desired location(s), as
described in the EMS-D10 Pilot’s User Guide > Global
Configuration Settings > Info Item Configuration section.

Sensor

Type

Ammeter Sensor

1 Dynon

P/N

100412-000

2 GRT

CS-01

If you are using the GRT CS-01 Hall effect sensor, you may
need to set the zero-point of the sensor. After you have selected a SENSOR TYPE of “2,” the
OFFSET parameter will be displayed. Adjust the OFFSET (in increments of 1 amp) until the
current displayed on the EMS Main page screen is correct at a known current.