26

Serial Data Output

The EFIS-D10 outputs text data through its serial port constantly during normal operation. This data is useful for a
variety of applications. All numbers are in decimal and are standard ASCII. To view the data using a terminal program,
the following settings should be used:

Baud rate:

115200

Data:

8

bit

Parity:

none

Stop:

1

bit

Flow control:

none

The format for the data being sent out the RS232 port is:

Char

Width

Description

Notes

1

2

Hour

00 to 23, current hour according to EFIS-D10A’s internal clock

3

2

Minute

00 to 59, current minute according to EFIS-D10A’s internal clock

5

2

Second

00 to 59, current second according to EFIS-D10A’s internal clock

7

2

Fractions

00 to 63, counter for 1/64 second. Data output frequency.

9

1

Pitch Sign

‘+’ or ‘-’ (positive means plane is pitched up)

10

3

Pitch

000 to 900, pitch up or down from level flight in 1/10 degrees (900 =
90