28

Char

Width

Description

Notes

38

2

Vertical G’s

00 to 99, vertical G’s in units of 1/10 G (99 = 9.9 G’s)

40 2

Angle

of

Attack

00 to 99, percentage of stall angle.

42 6

Status
Bitmask

An internal-use status bitmask containing 24 bits

48

2

Product ID

Ascii-hex Dynon product ID: 01=EFIS-D10A, 10=EFIS-D10,
03=EMS-D10

50

2

Checksum

The ascii-hex 2 byte sum of all 49 preceding bytes

52

2

CR/LF

Carriage Return, Linefeed = 0x13, 0x10

As an example, the following is what one line of serial data looks like:

00082119+058-00541301200+9141+011-01+1500

3EA0C701A4

<CR><LF>

This serial data can be logged using any standard serial terminal program such as Hyper Terminal. It can then be parsed
into its respective columns by many spreadsheet programs including Microsoft Excel.