WARNING

Electric Shock or Personal Injury Hazard.

When the lower plate Is removed for any reason, before reinstalling, be sure that all elec­

trical wires are routed in a manner that prevents them from coming Into contact with the
lower plate, lower plate screws, or any moving parts. Be sure that the wires are not

pinched in any way when the lower plate is reinstalled.

im'

- ■ 'itS'-■ i ........ .............. ..... ............

Two

Locking

Tabs

Before replacing any parts, disconnect the vacuum cleaner from the

electrical outlet.

Replacing some of the parts in this section involves the removal and

installation of the lower plate. Always place paper under nozzle any­

time the lower plate is removed to protect the floor surface.

To Remove Lower Plate.

Start by placing the handle in the upright position. See the

HANDLE ADJUSTMENTS section. Turn the vacuum cleaner over,

exposing the underside. Release the lower plate by removing the
two (2) screws and pressing inward on the two (2) locking tabs
that secure the lower plate, as shown in the illustration. Remove
the lower plate and remove any residue that may exist in the belt
area.

To Reinstall Lower Plate.

Hook the front end of lower plate into the slots on the front of the nozzle housing. Press the
lower plate into place until the locking tabs snap into place, then replace the two (2) screws.

NOTE:

To ensure maximum cleaning efficiency, the belt should be checked regularly to make

sure it is in good condition. Check to see if the belt is stretched, cracked, or if excessive slippage

has occurred. Replace if necessary.