SYSTEM APPLICATIONS

Caution:

1

.

Make sure that the cable length between the camera

site and the end of System Controller WV-CU300
should be less than 3,000 ft with RG-59U, BELDEN

9259 or equivalent cable.

2,

The cable length between the Sequential Switcher

WJ-SQ508 and the System Controller WV-CU300
should not be long due to no cable-loss compensator

on the System Controller.

A Basic Application

1. Single WJ-SQ508 without VTR

ALARM/SEQ OUT

6^00000

(a)

(b)

(c)

(d)

(e)

(0

(

9

)

(h)

Sequence time: Set by the Dwell Time Control (5) or

Program Switch (20),

Controls:

(

1

) Master/Slave Switch (27) to Master position,

(2)

Station Number Switch (29) & Unit Number Switch

(30) are not specified.

(3) Spot/Sequence Audio Switch (26) to OFF position.

Normal sequence mode:

(

1

)

SPOT/SEQ OUT —► switched by Dwell Time

Control (5).

(2)

ALARM/SEQ OUT —+ switched by Dwell Time

Control (5).

Program sequence mode:
(

1

) SPOT/SEQ OUT —» switched by Program Switch

(

20

).

(2) ALARM/SEQ OUT —> switched by Program Switch

(

20

).

Spot mode:

(

1

) SPOT/SEQ OUT

spot mode

(2) ALARM/SEQ OUT —+ sequential mode.
Single alarm mode:
(

1

) SPOT/SEQ OUT —> continues previous operation.

(2) ALARM/SEQ OUT —» fixed to the alarmed picture.

Multiple alarm mode:

(

1

) SPOT/SEQ OUT continues previous operation.

(2) ALARM/SEQ OUT —» starts sequencing the

alarmed pictures outonce every second.

Quick Scan alarm mode:

(

1

) SPOT/SEQ OUT

continues previous operation.

(2)

ALARM/SEQ

OUT —r

starts sequencing

all

pictures in QS-TIME.

2. Single WJ-SQ508 with VTR

ALARM/SEQ OUT

SPOT/SEQ OUT

ooodóooboSTj

óoodóoDoSo

®

ALARM OUT

RECOVER IN
RESET OUT

GND

(i) Quick Scan alarm mode:

(1) SPOT/SEQ OUT

i.

starts sequencing out once every second
when the unit was in SEQ mode.

ii.

stays spot mode when the unit was in SPOT

mode.

(2) ALARM/SEQ OUT —» start sequencing out all

pictures in QS- TIME.

3.

Parallel connection without VTR

SPOT/SEQ OUT ALARM/SEQ OUT

(A)

D-ODDbOO© Sj5T[§5

óoo©уo©у^_ ®

MTrrnTriTi

ALARM/SEQ OUT

(a)

(b)

(

2

)

(3)
(4)

(c)

(d)

(e)

(f)

(g)

(h)

Sequence time: Set by timing pulse from VTR
Controls:

(

1

) Master/Slave Switch (27) to Master position.

Station Number Switch (29) & Unit Number Switch

(30) are not specified.

Dwell Time Control (5) to EXT position.
Spot/Sequence Audio Switch (26) to OFF position.

Sequence stops when the power of VTR is turned off.

Normal sequence mode:

(

1

) SPOT/SEQ OUT —» switched by timing pulse of

VTR.

(2) ALARM/SEQ OUT —> switched by timing pulse of

VTR.

Program sequence mode:
(1) SPOT/SEQ OUT switched by timing pulse of

VTR through Program Switch (20).

(

2

) ALARM/SEQ OUT switched by timing pulse of

VTR through Program Switch (20).

Spot mode:

(

1

) SPOT/SEQ OUT —> spot mode

(2) ALARM/SEQ OUT —* sequential mode.
Single alarm mode:
(1) SPOT/SEQ OUT

i.

starts sequencing out once every second
when the unit was in SEQ mode.

ii.

stays spot mode when the unit was in SPOT
mode.

(2) ALARM/SEQ OUT —> fixed to the alarmed picture.

Multiple alarm mode:
(

1

) SPOT/SEQ OUT

i.

starts sequencing out once every second
when the unit was in SEQ mode,

ii.

stays spot mode when the unit was in SPOT
mode,

ALARM/SEO OUT —» starts sequencing the

alarmed pictures out once every second.

ó.oodbboo¿

bOOÓÓODÓil

!T5T

S

8

T

1 LlllJ i 1 1 1 ^

SPOT/ SEQ OUT

^

II

ALARM/SEQ OUT

p

(C)

óJooobooót

úooooooól

5^KíSíííSi]TíTtTiTi

br

TiTiTr

:^5<

(d) -Normal sequence mode:

(1)

SPOT/SEQ OUT All WJ-SQ508 are switched

by the Dwell Time Control (5) of (A) WJ-SQ508.

(2)

ALARM/SEQ OUT All WJ-SQ508 are switched

by Dwell Time Control (5) of (A) WJ-SQ508.

(e) Program sequence mode:

(1)

SPOT/SEQ OUT All WJ-SQ508 are switched

by Dwell Time Control (5) of (A) WJ-SQ508 with
programmed sequence order.

(

2

)

ALARM/SEQ OUT ^ All WJ-SQ508 are switched

by Dwell Time Control (5) of (A) WJ-SQ508 with
programmed sequence order.

(f)

Spot mode:

(

1

)

SPOT/SEQ OUT WJ-SQ508 in spot mode

shows the spot picture. Other WJ-SQ508 are
synchronized to the timing pulse of (A) WJ-SQ508.

(2)

ALARM/SEQ OUT WJ-SQ508 in spot mode

and the other WJ- SQ508 are synchronized to the
timing pulse of (A) WJ-SQ508.

(g) Single alarm mode:

(

1

) SPOT/SEQ OUT - When the unit (B) is alarmed,

i.

the unit (B) and (C) starts sequence in every

one second.

ii.

the unit (A) continues previous operation.

(2) ALARM/SEQ OUT —» WJ-SQ508 in alarmed mode

fixed to the alarmed picture. Other WJ-SQ508
continue the sequence mode.

(h) Multiple alarm mode:

(1) SPOT/SEQ OUT - When the unit (B) is alarmed,

i.

the unit (B) and (C) starts sequence in every
one second.

ii.

the unit (A) continues previous operation.

(2)

ALARM/SEQ OUT -+ Alarmed channels of

alarmed WJ-SQ508 start sequencing out once
every second.

(i)

Quick Scan alarm mode:

(

1

) SPOT/SEQ OUT - When the unit (B) is alarmed,

i.

the unit (B) and (C) starts sequence out

second.

ii.

the unit (A) continues previous a operation.

(2) ALARM/SEQ OUT The alarmed WJ-SQ508

starts to sequence out all pictures in QS-TIME.

Note:

The picture on each video monitor wilt not be
the same camera picture.

(a) Sequence time:

(B) (C) WJ-SQ508 are synchronized with (A) WJ-SQ508.

(b) Controls:

(1) Master/Slave Switch (27) to Master position for all

WJ-SQ508.

(2) Station Number Switch (29) & Unit Number Switch

(30) are not specified.

(3) Dwell Time Control (5) of (A) WJ-SQ508 to proper

position.

(4) Dwell Time Control (5) of (B) (C) to EXT position.
(5) Spot/Sequence Audio Switch (26) to OFF position.

(c)

Sequencing of (C) WJ-SQ508 stops when the power

of (B) WJ-SQ508 is turned off due to no timing pulse

from (B) WJ-SQ508.

(