External timing input connector (ext timing in), Password setting switch (password set), Power cord – Panasonic WJ-SQ508 User Manual

Page 7: Grounding screw, External tally connector (tally out), Note, Master/slave connectors (m/s in/out), Alarm output terminal (alarm out), Alarm signal input s terminals (alarm in), Recover input terminal (recover in)

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

32. External Timing Input Connector (EXT TIMING IN)

The sequential switching interval of WJ-SQ508 can be

externally controlled by a Time Lapse VTR.
Supply the timing pulse from the Time Lapse VTR to

this connector.

33. Password Setting Switch (PASSWORD SET)

The WJ-SQ508 contains a password function to

protect a program from being changed by unauthorized
persons. A password of five digits can be set by this

switch.

Refer to the setting up of the password on page

8

.

34. Power cord

35. Grounding Screw

36. External Tally Connector (TALLY OUT)

When using an external display in addition to the LEDs
of the Sequence Switch (3), the Spot Switches (4) and

the Program Switch (20), utilize this connector for the

external tally out signals.

The pin configuration is shown below.

An open collector output is provided to each pin. The

supply voltage is 16V DC maximum and the current is

100 mA

(D---------

-------

1

. PROG

-------

9

. GROUND

2 SEQ

- 10. SPOT 2

(

45

)--- -

3 SPOT

8

to; ■

(

0

>-------- -------l"l. SPOT1

4

.qpoTT

_

if?)____ _ - -

12

R «iPOT R

gj)----------- * -

- - -

(S^..........

0

\ 1 J

-------14,

7

QPnr

A

ij)

1

-

------- a SPOT 3

Note:

This connector can be used as a external remote

control connector. Ask qualified service personnel

for the modification of the circuit.

37. Spot Channel Output Connectors

(SPOT CH OUT 1-4 CH/5-8 CH)
The command signal of the "TALK" function is supplied

to the Spot Channel Input Connector (4) of the

WJ-DA464 from this connector.

Note:

1. The signal from 1-4 CH should be supplied to 1-4

CH of the Spot Channel Input Connector (4) of the

first WJ-DA464.

The signal from 5-8 CH should be supplied to 5-8
CH of the Spot Channel Input Connector (4) of the

second WJ-DA464.

Refer

to

the

operating

instructions

of

the

WV-CU300 for "TALK" function,

1

. TALK ALL

2. CH SEL

1

3. CH SEL 2
4. CH SEL 3

5. TALK SW

1

6

. GROUND

38. Master/Slave Connectors (M/S IN/OUT)

When multiple WJ-SQ508 are used in a master- slave
operation, connect the 5 pin interface cable (provided)
between these

connectors of the WJ-SQ508. A

master- slave control data signal transmits among the

WJ-SQ508.

1. SCKO

2. SBO

3. CNT I/O
4. TIM I/O

5. GND

39. Alarm Output Terminal (ALARM OUT)

When the Alarm Signal Input Connector (40) or the

Quick Scan Input Terminal (43) is activated, the alarm

output signal will be supplied from this connector. This

output consists of a open collector circuit. The supply

voltage is 16V DC maximum and the current is 100 mA

40. Alarm Signal Input s Terminals (ALARM IN)

A alarm sensor unit which has an open collector circuit

can be used with this input connector.
When this terminal is activated (grounded), the alarm

buzzer sounds and the Alarm Indicator (7) blinks. At

the same time, the signal at the Alarm/Sequence Video

Output Connector (22) outputs the video signal from

the alarmed camera site.

41. Recover Input Terminal (RECOVER IN)

The WJ-SQ508 returns to the normal operation mode

from the alarm mode when the recover signal from a
Time Lapse VTR is supplied to this connector.

Note;

When the alarm mode is canceled by the
WV-CU300,

the

Alarm

Indicator

(7)

of

the

WJ-SQ508 changes from a blinking state to the

continuously on state.

42. Reset Output Terminal (RESET OU'H

When a Time Lapse VTR receives the reset signal

supplied from this connector, the Time Lapse VTR

returns to the normal operation mode from the alarm
mode.

-

6

-

Advertising