FRONT PANEL

Rack Handle

Rack Handle

Q KNOB LOCKS’

PC4002 ONLY

O POWER SWITCH/POWER INDICATOR (RED)

Push this switch to turn the power ON, and push it again

to turn the power OFF. The red power indicator will light

when power is supplied.

©PROTECTION INDICATOR (RED)

This indicator will illuminate under two sets of circum­

stances: when power is first applied, a muting circuit is

in operation for about six seconds after power-up, to avoid

damage to speakers. This indicator will be lit at this time.

Additionally, if the protection circuitry is activated for any

reason (for instance, if a DC voltage exceeding ±2V ap­

pears at the output terminal), the speaker outputs will be

shut off, and this indicator will go on. It will stay on for

as long as power is applied and the condition which caused

the protection circuit to activate still applies. Once the

condition has been remedied, the indicator will go off, and

normal operation will be resumed.

©THERMAL FAN INDICATOR (RED)

If the fans are operating at high speed (ie a heat-sink

temperature of 80°C has been attained), this indicator will

go on.

O BTL INDICATOR (GREEN)

This indicator will be lit if the BTL (mono bridging rtiode)

switch on the back panel has been set ON.

©PEAK METERS (PC 4002M ONLY)

These large illuminated meters give a peak reading of the

output level from the amplifier. The bulbs illuminating these

meters are replaceable without soldering from the front

panel. The meters' zero points may also be adjusted from

the front panel.

SIGNAL INDICATORS (GREEN) (PC4002 ONLY)

These signal indicators light when the output signal level

is 2V or more (in the frequency range 20Hz-20kHz) to

confirm the input signal.

©CLIP INDICATORS

These LED indicators light up when the output distortion

of the respective channel reaches a level of about 1 %.

© INPUT ATTENUATORS

These allow attenuation of the input signals in IdB cali­

brations from 0-20dB, and in 2dB calibrations thereafter.

The controls are detented for a positive feel, and to help

with replicating settings.

© KNOB LOCKS (supplied)

Push these locks over the attenuation controls to prevent

accidental resetting of the levels. Pull them off again if you

need to reset the levels.

Advertising