Line in, Line out, Power source frequency set switch for timer – Yamaha MT44D User Manual

Page 6: Remote control terminal, Remote punch in/out, Voltage selector (general model only)

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

REAR PANEL

1. LINE IN

These are input terminals for rec»rding. For use
of this unit as a 2-channel deck, connect the

terminal 1 to the L-ch terminal and terminal 2 to
the R-ch terminal.

2. LINE OUT

These are output terminals for playback. For
use of this unit as a 2-channel deck, connect
the terminal 1 to the L-ch terminal and terminal
2 to the R-ch terminal.

3. Power source frequency set switch for TIMER

Set this switch to correct frequency according

to your local mains frequency. The switch is
set to 60 Flz when shipping from factory. .

4. REMOTE CONTROL terminal

The use of a RC 10B remote control unit (op­
tion) enables you to control the remote tape
driving process.

5. REMOTE PUNCH IN/OUT

The use of a remote control unit FS1 (option)
enables you to control the remote punch'in and
out process.

6. Voltage selector (General Model Only)

Set this to your local AC mains voltage. Failure
to do so will result in seriously impaired

performance or even severe damage.

Advertising