8.3 Description of Input/Output Signals

(1) Input/Output Signals

a) Input Signals (To Printer)

*DATA

: 8 bit parallel signal. (Positive logic)

*STB

: A strobe signal for reading in 8 bit data. (Negative logic)

*RESET

: A signal which resets the entire printer. (Negative logic. 1 ms or more)

b) Output Signals (From Printer)

*ACK

: This is a pulse signal for requesting 8 bit data, issued at the end of a BUSY signal.

(Negative logic)

*BUSY

: This signal indicates that your printer is in a BUSY state. New data should be input

when this signal is "LOW". (Positive logic)

*FAULT

: When your printer is in an alarm state, this signal is "LOW". At this time, all control

circuits of your printer are interrupted. (Negative logic)

*PE

: When the paper is near its end, this signal is issued. (Positive logic)

Note: An alarm condition occurs when the timing of the print head movement sensor is abnormal.

c) Power Source

*+5V DC

: The same +5V output as that of the power source which actuates the control circuits.

This should be less than 30 mA.

*GND

: The common circuit ground.

*FRAME GND

: Equivalent to "case ground".