CBM America CBM-720 User Manual

Page 48

Advertising
background image

CBM-710/720/730/750 User’s Manual

42

CITIZEN

(17) Skip Perforation Command

D8

D1

1st byte

0

0

0

1

1

0

1

1

ESC (1B)H

D8

D1

2nd byte

0

1

0

0

1

1

1

0

N (4E)H

D8

D1

3rd byte

N7

N6

N5

N4

N3

N2

N1

n (Binary digital)

This command feeds the paper (skips) n lines without any printing.

However, this cannot exceed the length of one page (1

n

126)

(18) Skip Perforation Cancel Command

D8

D1

1st byte

0

0

0

1

1

0

1

1

ESC (1B)H

D8

D1

2nd byte

0

1

0

0

1

1

1

1

0 (4F)H

This command cancels the skip perforation function.

(19) Validation Print Command

D8

D1

1st byte

0

0

0

1

1

0

1

1

ESC (1B)H

D8

D1

2nd byte

0

1

0

1

0

0

0

0

P (50)H

D8

D1

3rd byte

0

0

0

0

0

0

1

0

2 (02)H

Validation printing is performed by this command (one line only).

* This command cannot be used for printers with cutter specifications (Type A).

Advertising
This manual is related to the following products: