Noise gonsiderations, Transferring, Rernpval of the girille – Panasonic CW-1773SR User Manual

Page 11: Brain water, Noise, Eleetrlcal work, Gonsiderations

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Eleetrlcal work

Noise

Gonsiderations

Always use at the rated voltage.

Some installation locations may require installation of
a shortcircuit breaker.

A 10 Ampere time delay fuse or circuit breaker is

required.

Nominal cross sectionai area of power supply wire

must be 3 core x 1.0 mm^ or above.

The power supply must be from an independent circuit.

All electrical installation must be made in
accordance with local wiring and safety regulations
wherever applicable.

Please consult your dealer concerning installation
requirements.

Transferring

• When repositioning the air conditioner due to

renovations, or when transferring to a different
location, the removal and re installation of the unit

requires an additional service charge. Please consult

your dealer before moving. .

RernpVal of the girille

1) REMOVE AIR FILTER

2) REMOVE FRONT GRILLE

• Loosen the screws at the right, left and centre of the

grille.

• Press the side of the cabinet firmly and at the same

time pull the corner of the grille forward to

unhook the tabs.

• Slide the grille upward to free the two tabs at the

top of the grille from slots at the top of the cabinet.

CABINET

• Select an installation location that can support the

weight of the air conditioner and one that will not cause

increased operating noise and vibration.

• Ensure that airflow and noise from the rear side

of the unit (outdoors) when installed do not cause
inconvenience to neighbouring residents.

• Obstacles placed in front of the air outlet on the

rear side of the unit (outdoors), or covers placed

over it, cause excessive noise and a deterioration in

performance.

brain water

To get the maximum cooling efficiency this air

conditioner is designed to splash the condensate
on the condenser coil.

This method is called “Slinger-Up System”.

If the splashing sound annoys you, you can provide

an outside drain by using the following procedure

which may, however cause a small loss of

performance.

1. Slide out the chassis from the cabinet.

2. Remove the rubber plug from the body base plate.

(For cooling mode! only)

3. Install the drain pan prepared in the accessory kit to

the corner of the cabinet with 2 screws.

4. Connect the drain hose to the outlet on the drain pan

bottom.

5. Slide the chassis into its original place in the cabinet.

Note: Drain hose or tubing can be purchased locally to

satisfy your particular needs.