OEM Controls CANBus Product Line User Manual

Page 18

Advertising
background image

OM-17288

CANBus USERS MANUAL

Page 18 of 38

Revision C
GJO*07-12-06

ORIGINAL

I/O Test menus











These four screens are in the IO TEST menu. Pressing <MENU> will cycle
through them. When in a given screen, such as AI, use the <UP> and <DOWN>
keys to scroll through all of the system’s input or output signals.

Press <EXIT> to return to the top level menu screen.

CANBus menus








There is one display screen for each CANopen module in the system.

The first line is a 16-character string (put in by the application engineer) that
identifies the product type and additional information.

The second line shows the CANopen Node ID and the bus status which is one of –

-OPERATING normal

operation

per

CiA

spec.

-STOPPED

stopped per CiA spec

-PRE-OP

pre-operational

(just powered up) per CiA spec

-RESET

just performed a power-on reset per CiA spec

-NO DATA

the module is not communicating

AI 10 11 12 V
9.99 9.99 9.99

Di11 12 13 14 15
1 1 1 0 0

OCI-1 BRAIN
ID 0 OPERATING

OCO-1 MAIN BANK
ID 102 OPERATING

OCO-1 AUX BANK
ID 103 OPERATING

OCI-1 BUCKET JS
ID 64 NO DATA

Do35 36 37 38 39
1 1 1 1 0

VDD POWER SUPPLY
12.34 Volts

PWM 11 PWM 12
45.5 % 100.0 %

Advertising