AUXILIARY LOAD CONTROL

The Comfort Plus can be used to provide control signals to
other loads in the application. To do so, connect low voltage
control wires to the "COM" and "NC" or the "COM" and
"NO" positions of the low voltage terminal block in the
electrical compartment of the Comfort Plus system. (See
Figure 17.) These contacts are rated for 30 volts, 3 amps
maximum.

Installation

HUMIDIFIER/ELECTRONIC FILTER INSTALLATION

The Comfort Plus is capable of being connected to a humidifier and/or an electronic air filter. If installing either
of these devices, connections to the Comfort Plus system are made to the bottom two relays on the base I/O
relay board inside the system's electrical panel. Refer to the Line Voltage Wiring Diagrams (Page A.09-A.12)
for the location of these relays.

If installing a humidifier, connect it to the "HEAT CALL" relay on the base I/O relay board. This relay closes
during a heat call.

If installing an electronic air filter, connect it to the "FAN ON" relay on the base I/O relay board. This relay
closes during a fan call. The maximum filter size if using a Steffes Return Air Plenum is 20" x 25" x 2.

Maximum external load should not
exceed 60 VA on the system's class
II transformer.

IMPORTANT

TWO STAGE HEAT PUMP APPLICATION WITH VARIABLE SPEED BLOWER

FIGURE 16

TYPICAL AUXILIARY LOAD CONTROL

FIGURE 17

NOTE: During off-peak (charge) periods, the con-

tact is closed between "COM" and "NC".

W/

N

O

N

C

C

O

M

O

u

td

o

o

r

O

u

td

o

o

r

C

R

H/E

Y1-Y2

W-E

Y2

Y1

AUX

O

G

RP

2

2

Y1 Y2

2

O

AP

P

Inputs

Peak

Aux.

Relay

Auxiliary Control Relay

Relay Contacts

Relay Coil

COM

NO/NC

COM

NO/NC

W/

N

O

N

C

C

O

M

O

u

td

o

o

r

O

u

td

o

o

r

C

R

H/E

The Y1-Y2 Jumper must be removed.

A

Speed

Blower

Y1-Y2

W-E

Y2

Y1

AUX

O

G

RP

2

2

Y1 Y2

2

O

AP

P

R

L Y2 Aux G O/B C

Y

R

Honeywell TH5320U

Y1 - Compressor Stage 1

To Heat Pump

O - Reversing Valve

R - Low Voltage Hot

C - Low Voltage Common

Y2 - Compressor Stage 2

c

Inputs

Peak

Aux.

Relay

The W-E Jumper must be installed.

I M P O R T A N T

Thermostat

Stage

Thermostat

Output

Heat

Pump
Stage

% of

Selected

CFM

Heat Call
Status on

Digital Display*

Discharge Air

Temperature

Target

1

Y1/G

1

50% or 70%**

HC1

L048

2

Y1/Y2/G

2

100%

HC1

L048

3

Aux/Y1/Y2/G

2

100%

HC2

L049

Fan

G

0

400 cfm

HCF

N/A

Cool 1

Y1/G/O

1

50% or 70%**

COOL

N/A

Cool 2

Y1/Y2/G/O

2

100%

COOL

N/A

Emergency

H/E

0

100%

HC3

L049

Contractor Use Only

TWO STAGE HEAT PUMP

*

If multiple inputs are active, system
will display highest Heat Call values.

** Systems built before 1/1/2011 are

configured for 50% airflow in Stage 1.
For more information, refer to
Instruction #1200601-High Speed
Stage 1 Relay Installation.

Advertising