Ground lugs, Appendix, A.11 comfort plus – Steffes 4140 Owner & Installers Manual User Manual

Page 34

Advertising
background image

Appendix

A.11

Comfort Plus

Appendix

Line Voltage Wiring Diagram - Model 4130

240V OR 208V SYSTEMS ONLY

Use copper or aluminum conductors rated for 75

o

C or higher for field connection of this device.

NOTE: Line Voltage Field Wiring Connections - See Figure 10 for information on circuit phasing

connections.

DAMPER

BLOWER

LIMIT

CORE

BLACK/YELLOW

RED

75 VA

240v 24v

TRANSFORMER

WHITE/BLACK

RED

CORE

LIMIT

LIMIT

CORE

RED

BLACK/YELLOW

BASE IO BOARD

BLACK

BLACK

WHITE

160 °

CORE

N.C.

CORE

BLOWER

C

IR

C

U

IT

#

3

C

H

A

R

G

E

C

IR

C

U

IT

#

4

C

H

A

R

G

E

C

IR

C

U

IT

#

1

C

H

A

R

G

E

C

IR

C

U

IT

#

2

C

H

A

R

G

E

C

IR

C

U

IT

C

O

N

T

R

O

L

S

B

L

O

W

E

R

S

/

L2 120

NO

FAN ON

RELAY

RESISTOR

RESISTER

L2 240

BLOWER

RELAY

BLUE/WHITE

NO

HEAT CALL

COM

COM

COM

L1

1/4 Amp

5 Amp

NO

COM

NO

15A

60A

60A

60A

60A

B

R

O

W

N

B

L

A

C

K

R

E

D

B

L

U

E

#2

Element 2

Element 1

Element 3

Element 4

EXPANSION

ELEMENT 5

L1

L2 240

BOARD

L2 120

NO

1/4 Amp

COM

COM

COM

BOARD

HEATING ELEMENTS

NO

COM

COM

NO

ELEMENT 11

COM

NO

ELEMENT 12

NO

COM

Element 7

Element 5

Element 6

Element 8

Element 9

#1

ELEMENT 6

NO

NO

COM

COM

NO

COM

Element 12

Element 10

Element 11

NO

NO

L2 120

L2 240

EXPANSION

L1

1/4 Amp

ELEMENT 7

ELEMENT 8

ELEMENT 9

ELEMENT 10

NO

COM

NO

COM

COM

ELEMENT 1

COM

ELEMENT 3

NO

COM

NO

ELEMENT 2

NO

COM

NO

ELEMENT 4

To

To

To

Element

2,6,10

Relays

Element

1,5,9

Relays

Element

3,7,11

Relays

To

Element

4,8,12

Relays

GROUND

LUGS

in the base of the

BLUE

9 Pin Header

Connectors located

VARIABLE SPEED BLOWER

BLACK

BLACK

B

L

U

E

/B

L

A

C

K

N.C.

BLUE/WHITE

N.C.

160 °

MANUAL RESET

BLUE

190 °

B

L

U

E

/B

L

A

C

K

Heater & Plenum

SEE NOTE

Advertising