Steffes 4140 Owner & Installers Manual User Manual

Page 22

Advertising
background image

Installation

3.14

Comfort Plus

Installation

C006 Output Control Configuration - Configures the output controls of the Comfort Plus system. To deter-

mine the value, check the options desired from the list below. Then, add the numbers from the “Value”
column and enter the sum into this location.

Value

Option Selected

2

All 3100 Series Systems.

3

All 4100 Series Systems.

8

Enables compressor control if there is a "COOL" call during a peak (control) time.

32

If it is a peak (control) period and the Comfort Plus receives a cooling call, the com-
pressor will turn off and on in 20 minute intervals (off 20 minutes, on 20 minutes, off 20
minutes, etc.).

128

Interfaces Comfort Plus with a heat pump that has a reversing valve which is energized
for heating.

C007 Charge Factor - This configuration should be set to a value of 30.

C008 through C010 configurations are only applicable if the Comfort Plus system is being used in
conjunction with a heat pump.

C008 Heat Pump Compressor Outdoor Lock-Out Temperature for Off-Peak or Anticipated Peak

Modes - Indicates the outdoor temperature at which the heat pump’s compressor is locked out and not
allowed to operate during an off-peak or anticipated peak period.

C009 Heat Pump Compressor Outdoor Lock-Out Temperature for On-Peak Mode - Indicates the

outdoor temperature at which the heat pump’s compressor is locked out and not allowed to operate during
an on-peak period.

C010 Minimum Discharge Air Temperature - Sets the minimum discharge air temperature the system

targets during a Stage 1 heat call.

C011 Currently not utilized in the 3100/4100 Comfort Plus systems.

C012 Currently not utilized in the 3100/4100 Comfort Plus systems.

C013-C021 Time Clock Module Configuration - These configuration settings are used to configure the

peak control times when utilizing the optional Steffes Time Clock Module. Refer to the installation
and configuration instructions included with the module for more information.

* Power Company controls vary from one area to another. Check with the power provider for the

proper setting.

Configuration

Number

3100 Series

4100 Series

Heat Pump

No Heat

Pump

Heat Pump

No Heat

Pump

Reversing Valve

Energized for

Cooling

Reversing Valve

Energized for

Heating

Reversing Valve

Energized for

Cooling

Reversing Valve

Energized for

Heating

C006

2

130

2

3

131

3

C007

30

30

30

30

30

30

C008

5°F

5°F

5°F

5°F

5°F

5°F

C009

5°F

5°F

5°F

5°F

5°F

5°F

C010

90°F

90°F

115°F

90°F

90°F

115°F

C011

70°F

70°F

70°F

70°F

70°F

70°F

C012

60°F

60°F

60°F

60°F

60°F

60°F

C013 - C021

Refer to the Time Clock Installation Instructions