Electronic air filter installation, Position low voltage terminal block coding, Installation – Steffes 8188 User Manual

Page 22

Advertising
background image

I

NSTALLATION

„

3.13

T

HERM

E

LECT

ELECTRONIC AIR FILTER INSTALLATION

The ThermElect system is capable of being connected to an electronic air filter. Connections to the ThermElect
system are made to the bottom left relay (FAN ON) on the Base IO Relay Board inside the system's electrical
panel. This relay closes during a fan call. Refer to the Line Voltage Wiring Diagrams (Page A.04-A.05) for the
location of this relay.

THERMOSTAT CONNECTIONS (Stand Alone Furnace Application)

FIGURE 19

W

G

Y

R

Thermostat Switches

Y (Compressor)
C (Low Voltage Common)

Outdoor Sensor

SC

OS

W2

Y Y2

G

W

R C

12 Position Terminal Block

RS

G

Y

C

R

W

Temperature

Sensor Connections

Terminals for Connection as a Stand Alone Furnace

Honeywell T8401C1015

A Single Stage Heating

and Cool Room Thermostat

Optional Freeze Protection

Room Sensor

Air Conditioner Connections
(If being used in the application)

12-Position Low Voltage Terminal Block Coding

O = Reversing Valve Input

O2 = Reversing Valve Output

E = Emergency Heat

OS = Outdoor Temperature Sensor
SC = Outdoor Temperature Sensor Common
RS = Freeze Protection Room Temperature Sensor

R = Low Voltage Hot

C = Low Voltage Common

Y = Compressor/Stage 1 Heat Call

W = Stage 2 Heat Call

Y2 = Compressor Output

G = Fan Call

Installation