Control connection diagram – Chamberlain door opener User Manual

Page 36

Advertising
background image

C O N T R O L C O N N E C T I O N D I A G R A M

IMPORTANT NOTES:
1. The 3-Button Control Station provided must be connected for operation.
2. If a STOP button is not used, a jumper must be placed between terminals 4 and 5.
3. When adding accessories, install them one at a time and test each one after it is added to ensure proper installation and operation
with the Commercial Door Operator.

OPEN / CLOSE

3 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER AND STOP BUTTON

2 OR MORE

KEY LOCKOUT

R1

R2

R3

7

6

4

5

Stop

Close

Open

Stop

Close

Open

7

6

4

5

Stop

Close

Open

2 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER

STANDARD

7

6

4

Close

Open

D1 & E2

MODE ONLY

2 OR MORE

7

6

4

Close

Open

Close

Open

D1 & E2

MODE ONLY

OPEN / CLOSE

1

4

B2, T, TS & FSTS

MODE ONLY

Any Commercial Type

LiftMaster Brand Receiver

1 BUTTON STATION OR ANY AUXILIARY DEVICE

RADIO CONTROLS

SENSING DEVICE TO REVERSE OR STOP

EXTERNAL INTERLOCK

11

8

2

3

2

3

Remove Factory Installed Jumper

When Interlock is Used

ONE

2 OR MORE

STANDARD

7

6

4

5

Stop

Close

Open

All Wiring Types

Keyswitch

Sensing Device

10

Maintenance

Alert LED

10

10

Maintenance

Alert LED

Maintenance

Alert LED

(RED)

(WHITE)

(RED)

(WHITE)

(RED)

(WHITE)

Note: 11 and 4 are both the same common.

Either is acceptable.

See note 2.

See note 2.

See note 2.

©2009, The Chamberlain Group, Inc.

01-19460L

All Rights Reserved