Synchronisation


The sequencer can be synchronized with Midi in or Sync in (Roland)!




Midi-Clock to Sync out:

If the synchronisation switch is in the position Midi in, a Midi Clock of a Midi-master
synchronises the bassline.

At the Sync socket there is a Sync Out signal that can be used to synchronise other
gear with Sync In.



Sync-Slave:

If the synchronisation switch is in the position Sync In, an external Sync Master
synchronises the bassline.



Sync-Master:

If the synchronisation switch is in the position Sync Out, the bassline is the Sync
masters and used the internal clock generator.

At the Sync socket a Sync Out signal can be used to synchronize other gear with
Sync In.