WIRING

IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT

MUST BE REPLACED WITH A WIRE OF AT LEAST 105 DEGREE C TEMPERATURE RATING.

CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIR-

ING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION.

VERIFY PROPER OPERATION AFTER SERVICING.

Page 15

WIRING DIAGRAM - WOW253 & WOW254

WIRING DIAGRAM - WOW403 & WOW404

WOW403,

WOW404

LADDER

P/N 91466 08/2005

P/N 91467 08/2005

WOW403,WOW404

PICTORIAL

WOW253,

WOW254

PICTORIAL

Thermostat

P

ur

pl

e

R

ed

W

h

it

e

B

la

ck

B

la

ck

O

ra

ng

e

R

ed

Black

Black

R G W C

Pressure

Switch

Gas

Valve

Draft

Inducer

Circulating

Blower

Limit

Switch

Yellow

Ground

24 V

CMB Blower

Brown

Circuit Board

Transformer

Black

ACC

AC8 COOL

L1

Blue

24
VAC

Green

WOW253,

WOW254

LADDER

Gas Valve

P r e s s u r e

Switch

Limit Switch

Thermostat

24 VAC

CIRCUIT BOARD

115 VAC

Draft Inducer

Circulating

Blower

Gas Valve

P r e s s u r e

Switch

Limit Switch

Thermostat

24 VAC

CIRCUIT BOARD

115 VAC

Draft Inducer

Ignitor

Circulating

Blower #1

Circulating

Blower #2

Thermostat

Black

Black

P

ur

pl

e

Gas

Valve

Pressure

Switch

R

ed

W

h

it

e

O

ra

ng

e

Yellow

Limit

Switch

Ground

L1

Gray

Brown

R

ed

24 V

Blue

24

VAC

Transformer

Black

B

la

ck

B

la

ck

Green

Draft Inducer

C i r c u l a t i n g

Blower #1

C i r c u l a t i n g

Blower #2

CMB Blower

Circuit Board

R G W C